PC NC Maintenance Manual The VS-626M5
4-140
(4) Control Constant Display Mode
To check data or set/change a constant in the control constant dis-
play mode, follow the example below, in which C1-10 (soft-start
time) is to be changed.
Description
Key
Sequence
Digital Operator
Display
Remarks
C1-01 is displayed.
Move blinking cursor to the data
number.
Depress the [>] key once more
to return the blinking cursor.
Select C1-10.
Display C1-10 data contents.
Select data line to be changed.
Change set value. (1_¨5)
Write-in set value. Displayed for 0.5 seconds *
Returns to previous display
before write-in.
Return to control constant num-
ber display.
RESET
DATA
ENTER
D
RESET
D
D
DATA
ENTER
D
DSPL
Vedere la pagina 160