PC NC Maintenance Manual The VS-626M5
4-124
Note: A terminal arrangement is seen when the connectors on the PC board are viewed from the engaged
part (front of the unit).
3. Input Method Selection
The inverter 1CN 12-bit digital reference and 6CN sequence input signal
can be input with 0V common, +24V common, or external common. The
wiring differs according to the input method used. For external common,
use +24V (20 to 26V) power supply for input signal.
Common connections are possible because the 1CN and 6CN common
lines are insulated.
8CN (Option)
20 SS 10 —
19 *SPB 9 CPA
18 SPB 8 *CPC
17 *SPA 7 CPC
16 SPA 6 +5V
15 *SPC 5 +5V
14 SPC 4 +5V
13 *CPB 3 0V
12 CPB 2 0V
11 *CPA 1 0V
9CN (Option)
14 — 7 *SPBO
13 — 6 SPBO
12 — 5 *SPAO
11 — 4 SPAO
10 — 3 *SPCO
9 — 2 SPCO
8—1SS
10CN (Option)
14 SIG- 7 —
13 SIG+ 6 —
12 +15V 5 0V
11 — 4 —
10 +12V 3 0V
9—2—
8—1SS
Commenti su questo manuale