PC NC Maintenance Manual The VS-626M5
4-92
Figure 4.6: Clearances for Open Chassis Type
When using an open chassis type converter (11kW or more) in combination with
an inverter (7.5kW or less), follow the installation procedure as shown below.
Figure 4.7: Installation
Converter
Inverter
5 mm (0.20 inches)
or more
(a) Front View
(b) Side View
Air
Air
150 mm (5.91 inches)
or more
Max. 70 mm
(2.76 inches)
150 mm (5.91 inches)
or more
28 mm (1.1inches)
57 mm (2.24inches)
Converter
Inverter
(11kW or more)
(7.5kW or less)