Yaskawa YASNAC PC NC Maintenance Manual Manuale Utente Pagina 140

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 139
The VS-626M5 PC NC Maintenance Manual
4-119
Note: 6CN 5 to 18 sequence input signals can be input with 0V common, +24V common or external com-
mon. Wiring differs according to input method.
FC3 29 Fault code 3
COM2 30 Fault code signal com-
mon
ZSPD 33 Zero-speed Open-collector output
Exclusive-use for
24VDC
Load current: 50mA or
less
C1-19
AGR 34 Speed agree C1-20, C1-38 bit 6
SDET 35 Speed detection C1-21, C1-40 bit 2
TDET 36 Torque detection C1-23
TLE 37 Torque limit _|
ORG 38 Load origin _|
ORE 39 Orientation completion C2-09, 10 or C3-09, 10
CHWE 40 Winding selection com-
pletion
_|
FLTL 41 Fault (Open at fault) _|
TALM 46 Minor fault _|
COM1 42 Sequence output signal
common
_|
FLTNO 43 Fault contact output
Closed between 43 and
45 at fault
Open between 44 and
45 at fault
Relay contact output
Exclusive-use for
24VDC
Load current: 1A or less
_|
FLTNC 44
FLTCOM 45
SM 47 Speedometer output 0 to +10V Load current:
2mA or less
C1-16, 54
0V 48 0V for speedometer _| _|
LM 50 Load ratio meter output 0 to +10V Load current:
2mA or less
C1-17, 54, 18, C1-40 bit 4
C1-38 bit 1, 0
C1-38 bit 7
0V 49 0V for load ratio meter _|
Table 4.28: Control Circuit Signals (6CN) (Continued)
Signal Number Function Signal Level Related Constants
Vedere la pagina 139
1 2 ... 135 136 137 138 139 140 141 142 143 144 145 ... 300 301

Commenti su questo manuale