10 Appendix
10.1.2 Parameters
10-18
Pn50B
2 Input Signal Selection 2
0000 to
FFFF
8883 After restart Setup
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classi-
fication
Reference
Section
N-OT Signal Mapping (Reverse run prohibited when OFF (open))
Reference
Section
0 Reverse run allowed when CN1-40 input signal is ON (closed).
4.3.2
1 Reverse run allowed when CN1-41 input signal is ON (closed).
2 Reverse run allowed when CN1-42 input signal is ON (closed).
3 Reverse run allowed when CN1-43 input signal is ON (closed) .
4 Reverse run allowed when CN1-44 input signal is ON (closed).
5 Reverse run allowed when CN1-45 input signal is ON (closed).
6 Reverse run allowed when CN1-46 input signal is ON (closed).
7 Reverse run prohibited.
8 Reverse run allowed.
9 Reverse run allowed when CN1-40 input signal is OFF (open).
A Reverse run allowed when CN1-41 input signal is OFF (open).
B Reverse run allowed when CN1-42 input signal is OFF (open).
C Reverse run allowed when CN1-43 input signal is OFF (open).
D Reverse run allowed when CN1-44 input signal is OFF (open).
E Reverse run allowed when CN1-45 input signal is OFF (open).
F Reverse run allowed when CN1-46 input signal is OFF (open).
Reserved (Do not change.)
/P-CL Signal Mapping (Torque Limit when ON (closed))
Reference
Section
0 Active when CN1-40 input signal is ON (closed).
4.6.2
1 Active when CN1-41 input signal is ON (closed).
2 Active when CN1-42 input signal is ON (closed).
3 Active when CN1-43 input signal is ON (closed).
4 Active when CN1-44 input signal is ON (closed).
5 Active when CN1-45 input signal is ON (closed).
6 Active when CN1-46 input signal is ON (closed).
7 Always active (fixed).
8 Not active (fixed).
9 Active when CN1-40 input signal is OFF (open).
A Active when CN1-41 input signal is OFF (open).
B Active when CN1-42 input signal is OFF (open).
C Active when CN1-43 input signal is OFF (open).
D Active when CN1-44 input signal is OFF (open).
E Active when CN1-45 input signal is OFF (open).
F Active when CN1-46 input signal is OFF (open).
/N-CL Signal Mapping (Torque Limit when ON (closed))
Reference
Section
0 to F
Same as /P-CL signal mapping
4.6.2
4th 3rd 2nd 1st
digit digit digit digit
n.
