5 Adjustments
5.7.2 Vibration Suppression Function Operating Procedure
5-54
(2) Operating Procedure
Step Display after Operation Keys Operation
1 Input a operation reference and take the following steps while repeating positioning.
2
Press the Key to view the main menu for the
utility function.
Use the or Key to move through the list,
select Fn205.
3
Press the Key. The display shown on the left will
appear.
Measure f: Measurement frequency
Setting f: Setting frequency [Factory-set to the set
value for Pn145]
If the setting frequency and actual operating fre-
quency are different, "Setting" will flash.
Note:
Frequency detection will not be performed if
there is no vibration or the vibration frequency
is outside the range of detectable frequencies.
The following screen will be displayed if vibra-
tion is not detected. If the vibration frequencies
are not detected, prepare a means of detecting
and measuring the vibration. When the vibra-
tion frequencies are measured, go to step 5 and
manually set the measured vibration frequency
to “Setting f.”
4
Press the Key. The displayed “Measure f” value
will be displayed as the “Setting f” value as well.
Example of measured waveform
5
If the vibration is not completely suppressed, select
the digit with the or Key, and press the
or Key to fine-tune the frequency “setting
f.” Skip this step and go to step 7 if the fine-tuning of
the frequency is not necessary.
Note: If the setting frequency and actual operating
frequency are different, "Setting" will flash.
㧾㨁㧺̆㧲㨁㧺㧯㨀㧵㧻㧺
̆
㧲㨚㧞㧜㧠㧦㧭㧙㨂㨕㨎ޓ㧿㨡㨜
㧲㨚㧞㧜㧡㧦㨂㨕㨎ޓ㧿㨡㨜
㧲㨚㧞㧜㧢㧦㧱㨍㨟㨥ޓ㧲㧲㨀
㧲㨚㧞㧜㧣㧦㨂㧙㧹㨛㨚㨕㨠㨛㨞
㧾㨁㧺̆㨂㨕㨎㧿㨡㨜̆
㧹㨑㨍㨟㨡㨞㨑㨒㧩㧜㧝㧜㧚㧠㧴㨦
㧿㨑㨠㨠㨕㨚㨓㨒㧩㧜㧡㧜㧚㧠㧴㨦
㧾㨁㧺̆㨂㨕㨎㧿㨡㨜̆
㧹㨑㨍㨟㨡㨞㨑㨒 㧩㧙㧙㧙㧙㧙㧴㨦
㧿㨑㨠㨠㨕㨚㨓㨒 㧩㧜㧡㧜㧚㧜㧴㨦
㧾㨁㧺̆㨂㨕㨎㧿㨡㨜̆
㧹㨑㨍㨟㨡㨞㨑㨒㧩㧜㧝㧜㧚㧠㧴㨦
㧿㨑㨠㨠㨕㨚㨓㨒㧩㧜㧝㧜㧚㧠㧴㨦
Position
Error
Torque
reference
㧾㨁㧺̆㨂㨕㨎㧿㨡㨜̆
㧹㨑㨍㨟㨡㨞㨑㨒㧩㧜㧝㧜㧚㧠㧴㨦
㧿㨑㨠㨠㨕㨚㨓㨒㧩㧜㧝㧞㧚㧠㧴㨦
Commenti su questo manuale