3.7 Comparison Instruction (!=)
3-8
3.7 Comparison Instruction (!=)
[Outline]
This instruction compare Source A with Source B and stores the comparison result in the bit output
(the result is ON when true).
[Format]
Symbol : !=
Full Name : Not Equal (A!=B)
Category : LOGIC
Icon :
[Parameter]
Parameter Name Setting
Source A · Any integer type, double-length integer type and real number type register
· Any integer type, double-length integer type and real number type register
with subscript
· Subscript register
· Constant
Source B · Any integer type, double-length integer type and real number type register
· Any integer type, double-length integer type and real number type register
with subscript
· Subscript register
· Constant
[Program Example]
If the value of MW00100 is not equal to 100, after the instructions operation are executed.