Yaskawa Ladder Works Programming Manual Manuale Utente Pagina 172

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 220
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 171
8.7 QUEUE TABLE READ Instructions (QTBLR,QTBLRI)
8-15
[Parameter]
Parameter Name Setting
Table Name Table name
Read Data · Register address (except for # and C registers)
· Register address with subscript
Parameter · Register address
· Register address with subscript
[Output] · Any integer type register (except for # and C registers)
· Any integer type register with subscript
· Subscript register
* possible to omit
[Status] · Any bit type register (except for # and C registers)
· Any bit type register with subscript
* possible to omit
[Program Example]
Column element data (element format assumed to be integer) from the table defined as TABLE1 is
stored for the number of column elements beginning with MW00100 using DW00010 to DW00012 as
a parameter table.
Vedere la pagina 171
1 2 ... 167 168 169 170 171 172 173 174 175 176 177 ... 219 220

Commenti su questo manuale

Nessun commento