YASKAWA VS MINI J7 Specifiche Pagina 35

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 44
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 34
Molded-Case Circuit Breaker (MCCB)
and Magnetic Contactor (MC)
Molded-Case Circuit
Breaker (MCCB)
Type DCR2-50A22E Type DCR2-10A25C Type RFN3AL504KD
Power Supply Magnetic
Contactor (MC)
Surge Suppressor
(Manufactured by Marcon Electronics)
200V Three-phase Input Series
Motor
Capacity
kW
VS mini J7 Model
CIMR-J7
?A?
Molded-Case Circuit Breaker (MCCB)
Without Reactor
Model
Rated Current A
Model Model Model
Rated Current A
Without Reactor With ReactorWith Reactor
Magnetic Contactor (MC)
0.1
0.2
0.4
0.75
1.5
2.2
3.7
20P1
20P2
20P4
20P7
21P5
22P2
23P7
NF30
NF30
NF30
NF30
NF30
NF30
NF30
3
3
5
10
15
20
30
NF30
NF30
NF30
NF30
NF30
NF30
NF30
HI-11J
HI-11J
HI-11J
HI-11J
HI-15J
HI-20J
HI-35J
HI-11J
HI-11J
HI-11J
HI-11J
HI-11J
HI-15J
HI-25J
3
3
5
10
10
15
20
200V Single-phase Input Series
Motor
Capacity
kW
VS mini J7 Model
CIMR-J7
?A?
Molded-Case Circuit Breaker (MCCB)
Without Reactor
Model
Rated Current A
Model Model Model
Rated Current A
Without Reactor With ReactorWith Reactor
Magnetic Contactor (MC)
0.1
0.2
0.4
0.75
1.5
B0P1
B0P2
B0P4
B0P7
B1P5
NF30
NF30
NF30
NF30
NF30
3
5
10
15
30
NF30
NF30
NF30
NF30
NF30
HI-11J
HI-11J
HI-11J
HI-15J
HI-35J
HI-11J
HI-11J
HI-11J
HI-15J
HI-20J
3
5
10
15
20
400V Three-phase Input Series
Motor
Capacity
kW
Coils of Magnetic Contactor
and Control Relay
200V
to
230V
Large-size Magnetic
Contactors
DCR2-50A22E
220VAC 0.5μF+200
250VAC 0.1μF+100
DCR2-10A25C
1000VDC 0.5μF+220
380 to 460V Units
Control
Relay
LY-2, -3
HH-22, -23
MM-2, -4
VS mini J7 Model
CIMR-J7
?A?
Molded-Case Circuit Breaker (MCCB)
Without Reactor
Model
Rated Current A
Model Model Model
Rated Current A
Without Reactor With ReactorWith Reactor
Magnetic Contactor (MC)
0.2
0.4
0.75
1.5
2.2
3.0
3.7
40P2
40P4
40P7
41P5
42P2
43P0
43P7
NF30
NF30
NF30
NF30
NF30
NF30
NF30
3
5
5
10
15
15
20
NF30
NF30
NF30
NF30
NF30
NF30
NF30
HI-11J
HI-11J
HI-11J
HI-11J
HI-15J
HI-15J
HI-20J
HI-11J
HI-11J
HI-11J
HI-11J
HI-11J
HI-11J
HI-15J
3
3
5
10
10
10
15
RFN3AL504KD
C002417
C002482
C002630
Model Specifications
Surge Suppressor
Code No.
Be sure to connect a MCCB between the power supply
and the input AC reactor.
Connect a MC if required.
Connect surge suppressors to coils in magnetic contactors, control relays, electromagnetic valves,
and electromagnetic brakes used as the VS mini J7 peripheral units.
VS mini J7
36
OPTIONS AND PERIPHERAL UNITS (Cont’d)
Vedere la pagina 34
1 2 ... 30 31 32 33 34 35 36 37 38 39 40 ... 43 44