12 Appendix
12.4.2 List of Parameters
12-32
* 1. Available for the software version 32 or later
* 2. To reduce any danger while setting up the linear servomotor, the factory settings are set to low values
(factory setting: 30%). After the servomotor has been set up, increase the settings of the parameters to the
required force. For details, refer to 9.2 Trial Operation Using SERVOPACK Internal References.
Parameter
No.
Name Setting Range Unit
Factory
Setting
Setting
Validation
Reference
Section
Pn406 Emergency Stop Force
0 to 800 1% 800 Immedi-
ately
9.6.3
Pn408 Force Function Switches −−
0000 Immedi-
ately
Pn409 Notch Filter Frequency
50 to 2000 1 Hz 2000 Immedi-
ately
10.4.10
Pn40A
Notch Filter Q Value *
1
50 to 400 0.01 70 Immedi-
ately
10.4.10
Pn40B Notch Filter 2 Frequency *
1
50 to 2000 1 Hz 2000 Immedi-
ately
10.4.10
Pn40C Notch Filter 2 Q Value *
1
50 to 400 0.01 70 Immedi-
ately
10.4.10
Pn480 Speed Limit during Force Control
0 to 5000 1 mm/s 5000 Immedi-
ately
9.9.4
Pn481 Polarity Detection Speed Loop Gain
1 to 2000 1 Hz 40 Immedi-
ately
9.2.3
Pn482 Polarity Detection Speed Loop Integral
Time Constant
15 to 51200 0.01 ms 3000 Immedi-
ately
9.2.3
Pn483 Forward Force Limit *2
0 to 800 1 % 30 Immedi-
ately
9.2.3
9.11.1
Pn484 Reverse Force Limit *2
0 to 800 1 % 30 Immedi-
ately
Pn500 Positioning Completed Width
0 to 250 1 reference
unit
7Immedi-
ately
9.8.5
Pn504 NEAR Signal Width
1 to 250 1 reference
unit
7Immedi-
ately
9.8.6
Pn505 Overflow Level
256 to 8388352 256 refer-
ence units
262144 Immedi-
ately
10.3.3
Pn506 Brake Reference - Servo OFF Delay Time
0 to 50 10 ms 0 Immedi-
ately
Pn508 Servo OFF - Brake Reference Waiting
Time
10 to 100 10 ms 500 Immedi-
ately
Pn509 Momentary Hold Time
20 to 1000 1 ms 20 Immedi-
ately
9.6.5
0
1
N/A
N/A
Uses a notch filter for force reference.
Notch Filter Selection 1
(Refer to 10.4.12)
4th
digit
3rd
digit
2nd
digit
1st
digit
n.
0
1
Uses the notch filter 2 for force reference.
Notch Filter Selection 2
1
(Refer to 10.4.12)
Reserved (Do not change)
Reserved (Do not change)