8.2 Operation in Utility Function Mode (Fn)
8-17
8
8.2.10 Motor Models Display (Fn011)
This mode is used for motor maintenance, set the parameter Fn011 to select the motor model check mode. If the
SERVOPACK has been custom-made, you can also check the specification codes of SERVOPACKs.
Step
Display after
Operation
Digital Operator Panel Operator Description
1 Press the DSPL/SET or MODE/SET Key to select the
utility function mode.
2 Press the UP or DOWN Key to select Fn011.
Note: The enabled digit blinks.
3 Press the DATA/ENTER Key once, or DATA/SHIFT
Key for more than one second to display the linear ser-
vomotor model and voltage code.
4 Press the DSPL/SET or MODE/SET Key to display the
servomotor capacity.
5 Press the DSPL/SET or MODE/SET Key, and the linear
scale type and resolution code will be displayed.
6 Press the DSPL/SET or MODE/SET Key to display the
SERVOPACK’s code for custom orders.
Note: The display “y.0000” means standard model.
7 Press the DATA/ENTER Key once, or DATA/SHIFT
Key for more than one second to return to the utility
function mode display Fn011.
DATA
ENTER
(DATA/ENTER Key)
DATA
(DATA/SHIFT Key)
(Press at least 1 s.)
Linear Servomotor Voltage
Data
Model
Type
01
02
200 VAC or 280 VDC
400 VAC or 560 VDC
Linear Servomotor Type
Data
Linear servomotor
40
Motor capacity in units of 10 W
The above example indicates 100 W.
Scale Pitch Multiplication
Data
Resolution
8-bit8
Linear Scale Type
Data
Type
Incremental00
DATA
ENTER
(DATA/ENTER Key)
DATA
(DATA/SHIFT Key)
(Press at least 1 s.)
Commenti su questo manuale