8.2 Operation in Utility Function Mode (Fn)
8-17
8
8.2.10 Motor Models Display (Fn011)
This mode is used for motor maintenance, set the parameter Fn011 to select the motor model check mode. If the
SERVOPACK has been custom-made, you can also check the specification codes of SERVOPACKs.
Step
Display after
Operation
Digital Operator Panel Operator Description
1 Press the DSPL/SET or MODE/SET Key to select the
utility function mode.
2 Press the UP or DOWN Key to select Fn011.
Note: The enabled digit blinks.
3 Press the DATA/ENTER Key once, or DATA/SHIFT
Key for more than one second to display the linear ser-
vomotor model and voltage code.
4 Press the DSPL/SET or MODE/SET Key to display the
servomotor capacity.
5 Press the DSPL/SET or MODE/SET Key, and the linear
scale type and resolution code will be displayed.
6 Press the DSPL/SET or MODE/SET Key to display the
SERVOPACK’s code for custom orders.
Note: The display “y.0000” means standard model.
7 Press the DATA/ENTER Key once, or DATA/SHIFT
Key for more than one second to return to the utility
function mode display Fn011.
DSPL
SET
(DSPL/SET Key)
MODE/SET
(MODE/SET Key)
DATA
ENTER
(DATA/ENTER Key)
DATA
(DATA/SHIFT Key)
(Press at least 1 s.)
Linear Servomotor Voltage
Data
Model
Type
01
02
200 VAC or 280 VDC
400 VAC or 560 VDC
Linear Servomotor Type
Data
Linear servomotor
40
DSPL
SET
(DSPL/SET Key)
MODE/SET
(MODE/SET Key)
Motor capacity in units of 10 W
The above example indicates 100 W.
DSPL
SET
(DSPL/SET Key)
MODE/SET
(MODE/SET Key)
Scale Pitch Multiplication
Data
Resolution
8-bit8
Linear Scale Type
Data
Type
Incremental00
DSPL
SET
(DSPL/SET Key)
MODE/SET
(MODE/SET Key)
Code for custom orders
DATA
ENTER
(DATA/ENTER Key)
DATA
(DATA/SHIFT Key)
(Press at least 1 s.)
Vedere la pagina 224